Skip to content
Global sound
Maintenance Break

Maintenance Break

Three Flags, No Fix: The RCA That Missed a Second Failure

· 8 min

Show notes

A 785C A-frame bearing failed. Two days of unscheduled downtime, a line bore, a proper RCA.
The RCA was genuinely good. The site found the bearing hadbeen installed wrong six months earlier, rewrote the install procedure, added QA checkpoints. Textbook root cause work.
Pete and Drew walk through what that RCA missed: an existing 1000-hour PM check had already flagged that same bearing out of spec, three times, and none of those flags ever made it into the CMMS. Once the site dug further, the same gap held across the whole mobile work group, not just the one bearing.