Notes d’épisode
Are 30:2, 10 breaths/min and 400–600 mL evidence-based? ILCOR 2005 wrote "insufficient evidence" for any ratio and chose 30:2 to simplify teaching. The 10/min warning traces to Aufderheide 2004 (abstract: 13 intubated patients bagged at ~30/min, none survived at any rate) plus pigs (6/7 survived at 12/min vs 1/7 at 30). ILCOR's 2026 review: 11 studies, 3 pilot RCTs, 123 patients, all very low certainty; the only rate RCT found 10 vs 20/min no different (ROSC 48% vs 52%, n=46). ILCOR now suggests 30:2 or 10/min and 400–600 mL (weak, very low) and calls the evidence conflicting. CCC…