Gritty Sprinkler Fitter
av CaseyJames669
NFPA 13 Hangers & Supports: Spacing, Rod Sizes & Fasteners…
Om den här podden
Two Minnesota sprinkler fitters: FIELD, a beat-up old journeyman who's hung more pipe than you've walked past, and CODE, a cocky apprentice who's read the book twice and thinks that makes him dangerous. Raw, 18+ late-night talk on the MN Journeyman Sprinkler Fitter exam, built on the MSFC, NFPA 13, 14 and 25 and Minnesota rules, checked against the text, not barstool lore.
Made by fitters who still work the job, for the brothers and sisters trying to get that card. Pair it with the MN Journeyman Exam Prep app. New episodes every day.
Avsnitt
De 20 senaste av 187 avsnitt
- NFPA 13 Hangers & Supports: Spacing, Rod Sizes & Fasteners (Non-Seismic) | MN Journeyman Exam Prep · 47 minHolding the pipe up, no sway bracing. Five times water-filled plus 250 lb vs. what the building has to carry, listed vs. unlisted parts, rod and U-hook sizes, fasteners in…
- NFPA 13 Sprinkler Spacing & Protection Area: Light, Ordinary & Extra Hazard | MN Journeyman Exam Prep · 45 minHow far apart, how far off the wall, and how much floor one standard spray head is allowed to cover. We walk the S x L method, the light/ordinary/extra hazard and storage tables…
- NFPA 2001 Clean Agents & MSFC 904.10: Design Concentration, Discharge Time, Hold Time & Inspections | MN Journeyman Exam Prep · 44 minClean agent systems: NFPA 2001 and Minnesota 904.10. Halocarbons vs. inert gases, safety factors, the 10-second discharge, the 85%/10-minute hold, abort vs. manual release, and…
- NFPA 72 & MSFC 903.4 Sprinkler Supervision: Waterflow, Tamper, Supervisory Signals & Exterior Alarms | MN Journeyman Exam Prep · 43 minThe alarm side of sprinklers: NFPA 72 and Minnesota 903.4. Waterflow in 90 seconds, tamper switches in two turns, supervisory pressure, level and temperature numbers, test…
- NFPA 20 Fire Pumps & MSFC 913: Suction, Relief Valves, Pump Rooms & Acceptance Tests | MN Journeyman Exam Prep · 46 minFire pumps, NFPA 20 and Minnesota 913. Suction rules that keep pumps alive (zero psi at 150%, OS&Y only within 50 feet, ten pipe diameters, eccentric reducers), circulation and…
- NFPA 14 Standpipes & MSFC 905: Classes, Pressures, Flows & Minnesota Hose Connections | MN Journeyman Exam Prep · 47 minStandpipes, NFPA 14 and Minnesota 905. Classes I, II and III, wet vs. dry vs. manual vs. semiautomatic, pressure limits and PRVs, flow rates, and Minnesota's own modification for…
- NFPA 10 Portable Fire Extinguishers: Ratings, Placement, Inspection & Hydro | MN Journeyman Exam Prep · 50 minHalloween special: portable fire extinguishers. Ratings, placement and travel distance, monthly inspections, annual maintenance, and hydro intervals under NFPA 10 and MSFC 906…
- NFPA 24 Underground Mains: Bury Depth, Thrust Restraint, Flushing & Hydro | MN Journeyman Exam Prep · 47 minUnderground private fire service mains: bury depth, thrust blocks and restraint, flushing flows, and the hydro test. Everything that goes in the dirt before the riser. The usual…
- NFPA 22 Water Tanks: Heating, Suction Tanks, Vortex Plates & Levels | MN Journeyman Exam Prep · 51 minWater tanks for fire protection, the NFPA 22 way. We dig into tank heating and the 40-degree rule, suction tanks, vortex plates, and the level and temperature supervision numbers…
- Seismic Protection: Flex Couplings, Clearance, Sway Bracing & Restraint | MN Journeyman Exam Prep · 19 minSeismic protection for sprinkler piping, for the Minnesota journeyman sprinkler fitter exam. Minnesota pins NFPA 13-2016, where this is section 9.3. NFPA 13-2019 moved it to…
- NFPA 13R Low-Rise Residential | MN Journeyman Exam Prep · 29 minNFPA 13R, sprinklers for low-rise residential buildings (apartments, hotels, dorms, board and care), for the Minnesota journeyman sprinkler fitter exam. Every number comes from…
- NFPA 13D One- & Two-Family Dwellings | MN Journeyman Exam Prep · 34 minNFPA 13D, sprinklers for one- and two-family dwellings and manufactured homes, for the Minnesota journeyman sprinkler fitter exam. Minnesota pins 13D-2016 (Minn. R. 7511.8000)…
- Sprinkler Identification, Temperature Ratings & Spare Sprinklers | MN Journeyman Exam Prep · 28 minSprinkler identification, temperature ratings and spare sprinklers for the Minnesota journeyman sprinkler fitter exam. NFPA 13 (2016 6.2/8.3, the edition Minnesota pins, mapped…
- Occupancy Hazard Classification & Design Density | MN Journeyman Exam Prep · 41 minOccupancy hazard classification and what it does to your design, for the Minnesota journeyman sprinkler fitter exam. NFPA 13 (2016 ch.5/11, the edition Minnesota pins, mapped to…
- Pipe, Fittings & Joining Methods | MN Journeyman Exam Prep · 41 minPipe, fittings and joining methods, every rule a Minnesota journeyman sprinkler fitter needs for the exam. NFPA 13 (2016 chapter 6, the edition Minnesota pins, mapped to 2019…
- Antifreeze Systems | MN Journeyman Exam Prep · 45 minAntifreeze sprinkler systems, every rule a Minnesota journeyman sprinkler fitter needs for the exam. NFPA 13 (2016 section 7.6, the edition Minnesota pins, side by side with 2019…
- Dry Pipe & Preaction Systems | MN Journeyman Exam Prep · 60 minDry pipe and preaction systems (plus a little deluge), every rule a Minnesota journeyman sprinkler fitter needs for the exam. NFPA 13 (2016, the edition Minnesota pins, side by…
- Fire Department Connections | MN Journeyman Exam Prep · 55 minFire department connections, every rule a Minnesota journeyman sprinkler fitter needs for the exam. Minnesota State Fire Code 2020 Section 912: location approved by the fire code…
- Kitchen Hoods & Alternative Extinguishing Systems | MN Journeyman Exam Prep · 52 minMinnesota State Fire Code 2020 Section 904, the systems that aren't sprinklers but land on a sprinkler fitter's plate anyway. Minnesota's amended 904.1.1 service-personnel…
- Listener Prep Sheet: Deflectors, Obstructions, Sidewalls, Drains, Hangers & ITM | MN Journeyman Exam Prep · 1 h 1 minA listener handed us his LICENSING EXAM - PREP QUESTIONS study sheet, and we go through every line of it with the books open. NFPA 13 deflector position and how to measure below…